F-Gas Regulations 2027
What the Move to Low-GWP Refrigerants Means for Industrial Chiller Users
Changes to European F-Gas regulations are accelerating the development of industrial cooling equipment using refrigerants with a lower environmental impact. For manufacturers and businesses investing in new chillers, understanding these changes is becoming increasingly important when selecting equipment for long-term reliability, efficiency and regulatory compliance.
From January 2027, new restrictions under EU Regulation 2024/573 will affect the refrigerants permitted in certain industrial chillers and air conditioning equipment placed on the European Union market.
As a UK supplier of Cosmotec industrial cooling equipment, Newsome is following these developments closely, helping customers understand the available refrigerant technologies and select cooling systems appropriate to their operational requirements.
With Cosmotec introducing new low-GWP industrial chillers, businesses now have access to equipment designed to address changing environmental expectations while maintaining the performance required for industrial applications.
Why Are Industrial Chiller Refrigerants Changing?
Refrigerants are essential to the operation of industrial chillers, allowing heat to be removed from water, glycol and other process cooling circuits.
However, some conventional refrigerants have a high Global Warming Potential (GWP), meaning they can contribute significantly to climate change if released into the atmosphere. GWP provides a measure of the climate impact of a greenhouse gas compared with carbon dioxide over a specified period, commonly 100 years. A refrigerant with a GWP of 2,000, for example, has a substantially greater potential warming effect per kilogram released than one with a GWP below 150. For many years, industrial cooling equipment has used refrigerants such as R134a, R407C and R410A. Although these refrigerants have provided reliable performance, their relatively high GWP is driving the development of alternative technologies.
The transition is not simply about changing the refrigerant inside an existing machine. Different refrigerants have different operating characteristics, safety classifications and performance requirements. Manufacturers must therefore consider compressor compatibility, system design, operating pressures, energy efficiency and safety when developing new equipment.
What Changes Are Coming in 2027?
EU Regulation 2024/573 introduces a series of restrictions intended to reduce the use of high-GWP fluorinated refrigerants.
For stationary chillers placed on the EU market, two important changes take effect from 1 January 2027.
| Chiller cooling capacity | EU refrigerant restriction from January 2027 | ||
| Up to and including 12 kW | Fluorinated refrigerants must generally have a GWP below 150 | ||
| Above 12 kW | Fluorinated refrigerants must generally have a GWP below 750 |
Specific safety-related exemptions can apply, subject to the requirements of the regulation. These restrictions primarily concern the placing of new equipment on the EU market. They do not mean that every existing chiller using a higher-GWP refrigerant must automatically be removed from service in January 2027.
What About Industrial Chillers in the UK?
The regulatory position is different for businesses operating in Great Britain.
Although the UK and EU share the objective of reducing emissions from fluorinated greenhouse gases, Great Britain currently operates under its own F-Gas framework. The EU’s January 2027 equipment restrictions should therefore not be treated as an automatic legal deadline for all new industrial chillers supplied in England, Scotland or Wales. Northern Ireland continues to follow relevant EU F-Gas requirements.
Nevertheless, the European regulations are influencing the design and availability of industrial cooling equipment across the wider market. For UK businesses investing in new chillers, understanding the direction of refrigerant development is important when considering future equipment availability, maintenance requirements and long-term investment.
Understanding the Different Low-GWP Refrigerant Options
There is no single refrigerant that is suitable for every industrial cooling application. Selecting an appropriate refrigerant involves balancing environmental performance with operating temperature, cooling capacity, energy efficiency and installation safety. Several refrigerants are becoming increasingly relevant to industrial chiller design.
R1234yf: Very Low Global Warming Potential
R1234yf is a hydrofluoroolefin (HFO) refrigerant with a GWP of approximately 0.5 under the current EU regulatory methodology.
This makes it an attractive option for manufacturers developing cooling equipment with a very low direct climate impact from refrigerant emissions. R1234yf is classified as A2L, meaning it has lower flammability characteristics than highly flammable refrigerants but still requires appropriate safety considerations. Equipment using R1234yf must therefore be designed specifically for its operating characteristics and the intended installation environment. For compact industrial chillers, it provides a route towards meeting the EU’s stricter refrigerant limits.
R513A: A Non-Flammable Alternative
R513A has a GWP of approximately 631 under the values used by Cosmotec and is classified as A1, meaning it is non-flammable under the applicable refrigerant safety classification. Although its GWP is higher than that of R1234yf, it is considerably lower than that of several traditional industrial refrigerants. Its non-flammable classification can be particularly relevant where cooling equipment operates close to sensitive machinery, electrical systems or other environments where refrigerant flammability requires careful consideration. For chillers above 12 kW, R513A falls below the EU’s general 2027 GWP threshold of 750. For smaller chillers, its use under the EU rules may depend on the applicable safety exemption.
R32: An Established Refrigerant for Higher-Capacity Equipment
R32 is another refrigerant used in modern cooling and air conditioning systems. With a GWP of 675 and an A2L safety classification, it provides a lower-GWP alternative to certain older refrigerants. Its suitability depends on the equipment design, required performance and installation conditions. R32 is used in Cosmotec’s WLA Precision range, providing another option for industrial cooling applications.
How Cosmotec Is Responding to the Refrigerant Transition
Cosmotec has been developing its industrial cooling range to accommodate the changing refrigerant requirements. The manufacturer has introduced new refrigerant configurations across its WRA and WLA chiller families, selecting different technologies according to cooling capacity and application requirements. Newsome supplies when selecting Cosmotec industrial chillers to UK customers, providing technical advice and support equipment for manufacturing and process cooling installations.
Cosmotec WLA Compact Chillers
The WLA Compact range is designed for smaller industrial cooling duties where compact dimensions and reliable temperature control are important. Cosmotec has developed WLA Compact models using R1234yf, providing a very low-GWP refrigerant option for equipment with a cooling capacity of up to 12 kW. These units form part of the manufacturer’s transition towards lower-impact refrigerant technology.
Cosmotec WRA Industrial Chillers
The WRA range provides industrial process cooling across a broader range of capacities.
For smaller WRA models, Cosmotec has adopted R1234yf to address the requirements applying to equipment up to 12 kW. Larger WRA models use R513A, combining a lower GWP than many conventional refrigerants with the benefits of an A1 non-flammable classification. This allows different parts of the range to address their respective capacity and application requirements.
Cosmotec WLA Precision Chillers
For larger precision cooling applications, Cosmotec offers WLA Precision chillers using R32. These units provide another option for businesses requiring industrial cooling equipment developed around lower-GWP refrigerant technology. The choice between these ranges should be based on the actual cooling duty, required operating temperatures, installation conditions and other technical requirements.
Why Refrigerant Selection Matters Beyond Regulatory Compliance
Although the F-Gas transition is being driven by environmental legislation, the choice of refrigerant has broader implications for industrial cooling systems. A chiller is often a long-term investment, with its operating costs and reliability influencing production throughout its service life.
Energy Efficiency and Running Costs
A refrigerant with a lower GWP does not automatically make a chiller more energy-efficient. The electrical consumption of an industrial cooling system depends on the complete refrigeration circuit, compressor performance, operating temperatures, controls and the conditions under which the equipment operates. For this reason, businesses should consider both the direct environmental impact of the refrigerant and the indirect emissions associated with electricity consumption. A properly selected and efficient chiller can reduce energy costs throughout its operating life, making system performance an important part of equipment selection.
Safety and Installation Requirements
Refrigerant safety classifications also influence equipment design and installation. A2L refrigerants, including R1234yf and R32, require appropriate consideration of flammability-related risks. A1 refrigerants such as R513A provide an alternative where a non-flammable refrigerant is preferred or required. The correct choice depends on the manufacturer’s equipment design, the installation environment and the relevant safety requirements. It should not be assumed that a refrigerant can simply be substituted into existing equipment without technical assessment.
Long-Term Equipment Support
Industrial chillers are frequently expected to operate for many years. When selecting replacement equipment, businesses should consider how the refrigerant transition may influence future maintenance, refrigerant availability and the support offered by the manufacturer.
Choosing equipment from an established manufacturer with a clear refrigerant development strategy can help reduce uncertainty when planning long-term cooling investments.
Should Businesses Replace Their Existing Industrial Chillers?
The introduction of new EU F-Gas restrictions does not automatically mean that existing industrial chillers need replacing. For many businesses, properly maintained equipment can continue operating, subject to applicable legislation and refrigerant servicing requirements. However, the transition provides a useful opportunity to review older cooling installations, particularly where equipment is approaching the end of its expected service life. Businesses considering a replacement should assess the condition of the existing plant, maintenance costs, energy consumption and the availability of suitable alternative equipment.
Where a chiller has become unreliable or inefficient, replacing it with a modern system using an appropriate lower-GWP refrigerant may provide operational and environmental benefits. For production-critical applications, replacement planning should also consider how cooling will be maintained during installation and commissioning. Newsome can support customers with chiller selection, installation and associated temporary cooling requirements where continuity of service is essential.
Industrial Chiller Solutions from Newsome
As a supplier of Cosmotec industrial chillers, Newsome provides cooling equipment and technical support for a wide range of manufacturing and industrial applications. Our experience in process cooling allows us to assess the practical requirements of an installation, including cooling capacity, operating temperatures, fluid characteristics, hydraulic arrangements and the environment in which the equipment will operate.
With Cosmotec developing its WRA and WLA ranges around lower-GWP refrigerants, we can help customers understand the available options and select suitable equipment for their cooling requirements. The transition towards lower-GWP technology represents an important development for industrial cooling, but refrigerant selection remains only one part of specifying a reliable and efficient system.
The right industrial chiller must combine appropriate refrigerant technology with the cooling performance, operating efficiency and reliability required by the application.
Discuss Your Industrial Chiller Requirements with Newsome
Whether you are replacing ageing cooling equipment, planning a new process cooling installation or reviewing the refrigerants used within your existing plant, Newsome can provide technical advice on suitable Cosmotec industrial chiller solutions.
Contact Newsome to discuss your industrial cooling requirements and the latest low-GWP chiller options available.