MRI Chillers

MRI Chiller Sales, Hire or Lease from Newsome – experts in temperature control solutions.

Quick Enquiry

GDPR
This field is for validation purposes and should be left unchanged.

MRI chillers play a crucial role in maintaining the optimal operating temperature for MRI (Magnetic Resonance Imaging) machines, which are sensitive to temperature fluctuations. These chillers are specialised refrigeration systems designed to cool the components of the MRI machine, including the magnet, radiofrequency coils, and gradient coils, to ensure accurate imaging and reliable performance.

If you are looking to buy an MRI Chiller or need to rent one or multiple MRI chillers at short notice, then you need to get the advice of experts who understand the demands placed on MRI  chillers. Contact us here, at Newsome today to get the best technical advice possible, and make sure you get the right MRI chiller solution for your hospital or health business.

MRI Chiller Systems

The MRI machine generates a considerable amount of heat during operation, primarily due to the electrical currents flowing through the superconducting magnets and the radiofrequency pulses used to excite hydrogen atoms in the patient’s body. If not properly cooled, this heat can degrade image quality, reduce system efficiency, and even damage sensitive components.

MRI chillers work by circulating a coolant, typically water or a water-glycol mixture, through a closed-loop system that absorbs heat from the MRI machine and transfers it to an external cooling source. These MRI chillers are equipped with high-capacity compressors, heat exchangers, pumps, and controls to regulate the temperature of the coolant and ensure consistent cooling performance.

One of the critical factors in MRI chiller design is reliability. MRI machines often operate 24/7 in clinical settings, so the chillers must be robust and dependable to minimise downtime and prevent disruptions to patient care. Manufacturers employ advanced engineering techniques and quality components to build chillers capable of meeting the demanding requirements of MRI systems.

Efficiency is another important consideration. While maintaining precise temperature control, MRI chillers strive to minimise energy consumption to reduce operating costs and environmental impact. Modern chillers incorporate energy-efficient components and intelligent control algorithms to optimise cooling performance and minimize power usage. In addition to reliability and efficiency, MRI chillers must also meet stringent safety standards. Since they are often installed in medical facilities, these MRI chillers must comply with regulations governing electrical safety, refrigerant handling, and noise emissions to ensure the well-being of patients, healthcare professionals, and the surrounding environment.

MRI Chiller Maintenance

MRI chiller maintenance is a critical aspect of ensuring the reliable and efficient operation of magnetic resonance imaging (MRI) systems. Proper chiller maintenance helps prevent equipment downtime, ensures image quality, and extends the lifespan of both the chiller and the MRI system.

Regular cleaning of the chiller’s condenser and evaporator coils is essential to maintain optimal heat transfer efficiency. Dust, dirt, and debris can accumulate on these coils over time, reducing cooling capacity and increasing energy consumption. Here at Newsome, our technicians inspect the coils for any signs of corrosion, leaks, or damage that could impact performance.

MRI chillers use specialised coolant fluids to remove heat from the system. Periodic analysis of the coolant fluid helps identify any contaminants, degradation, or chemical imbalances that may affect MRI chiller performance. We test coolant samples for pH levels, conductivity, and the presence of contaminants such as dirt, rust, or microbial growth. Based on the analysis, we may recommend flushing and replenishing the coolant to maintain optimal performance.

Proper refrigerant management is crucial for maintaining chiller efficiency and compliance with environmental regulations. Our technicians check refrigerant levels, inspect for leaks, and ensure proper refrigerant charging to optimise cooling performance and prevent environmental harm.  MRI chillers rely on complex electrical systems to regulate temperature and control operation. At Newsome we inspect electrical connections, wiring, and components for signs of wear, damage, or overheating. We also verify that safety features such as overload protection and emergency shutdown systems are functioning correctly. Vibration analysis helps identify potential mechanical issues such as worn bearings, misalignment, or imbalance in chiller components.

MRI Chiller Manufacturers – Maintenance Schedules

Following the manufacturer’s recommended maintenance schedule is essential for ensuring the long-term reliability and performance of MRI chillers. This may include tasks such as lubrication of moving parts, inspection of seals and gaskets, and calibration of temperature and pressure sensors. Maintaining detailed records of all maintenance activities, including inspections, repairs, and fluid analysis results, is essential for tracking MRI chiller performance over time and ensuring compliance with regulatory requirements.

MRI Chiller Repairs

MRI chiller repairs require precision, expertise, and a deep understanding of the intricate systems that keep magnetic resonance imaging (MRI) machines running smoothly. When a chiller malfunctions, it’s not just a matter of inconvenience—it can disrupt critical medical procedures and compromise patient care. Repairing an MRI chiller demands swift action and meticulous attention to detail. The process begins with a thorough assessment of the chiller’s condition. Highly trained Newsome technicians meticulously inspect every component, from the condenser coils to the electrical connections, searching for signs of wear, damage, or malfunction. Using advanced diagnostic tools and techniques, we pinpoint the root cause of the problem, whether it’s a faulty compressor, a refrigerant leak, or an electrical issue.

Once the issue is identified, the repair process kicks into gear. The Newsome team work methodically to disassemble the chiller, carefully removing and replacing damaged parts with precision-engineered components. Every step is executed with care, ensuring that the MRI chiller is restored to optimal working condition. But repairing an MRI chiller isn’t just about fixing what’s broken—it’s about preventing future problems as well. We take proactive measures to reinforce weak points, upgrade outdated components, and implement preventive maintenance strategies that keep the MRI chiller running smoothly for years to come.

Throughout the repair process, communication is key. We keep healthcare providers informed every step of the way, providing updates on progress and offering insights into potential issues that may arise in the future. This transparency builds trust and confidence, assuring medical professionals that their equipment is in capable hands.

Finally, once the chiller repairs are complete, the chiller undergoes rigorous testing to ensure that it meets the highest standards of performance and reliability. Only when our  technicians are satisfied that the chiller is functioning flawlessly is it returned to service, ready to support lifesaving medical procedures with confidence and precision.

MRI Chiller Service

MRI chiller service encompasses a comprehensive range of activities aimed at maintaining, optimising, and ensuring the reliable operation of chillers used in magnetic resonance imaging (MRI) systems. Unlike reactive repairs, MRI chiller service is a proactive approach that focuses on preventive maintenance, regular inspections, and continuous monitoring to minimise downtime and maximise performance. At the heart of MRI chiller service is preventive maintenance. Highly skilled engineers at Newsome adhere to manufacturer-recommended schedules, conducting routine inspections, cleaning, and lubrication to keep chillers operating at peak efficiency. These proactive measures help prevent potential issues before they escalate, ensuring uninterrupted operation of MRI machines and preserving the quality of diagnostic imaging.

Why choose Newsome for your MRI Chiller needs?

When it comes to your MRI chiller needs, choosing Newsome is a decision rooted in experience, reliability, and unmatched support. Here are some key reasons why you should trust us for all your industrial chiller requirements:

High-Performance Cooling: Our extensive fleet of modern chillers is designed to deliver high-performance cooling. With reliable, quiet operation and low running costs, our equipment ensures that your cooling systems remain efficient and uninterrupted.

Comprehensive Range: Newsome offers a comprehensive range of chiller equipment, catering to a wide variety of applications and facility sizes. Whatever your cooling needs may be, we have the right solution to meet them effectively.

Decades of Expertise: With nearly 50 years of experience, Newsome has been a trusted name in the field of temperature and humidity control. Our long-standing commitment to providing specialist advice, equipment sales, hire, and maintenance services sets us apart.

Rigorous Testing: We take quality seriously. All our chiller equipment undergoes rigorous testing before being hired or dispatched. This ensures that the equipment functions perfectly upon arrival at your site, minimising any potential disruptions.

Multi-Site Capabilities: Newsome has the capability to provide MRI chiller services across multiple facilities. Our team offers full technical and maintenance support to ensure consistent performance across all your locations.

24/7 Support: Your operations don’t stop, and neither do we. We provide 24/7 support to our chiller clients, ensuring that our equipment continues to operate smoothly and remains in optimal working condition throughout your chosen support contract period.

Personalised Site Surveys: If you’re unsure about your MRI chiller requirements, our experienced engineering staff can visit your site. They will conduct a thorough site survey and make recommendations tailored to your specific needs, guaranteeing the right chiller equipment for your application.

Expert Advice: At Newsome, our knowledgeable chiller sales and maintenance support team is always ready to provide advice. We work closely with you to understand your business needs and ensure you get the perfect chiller solution.

Competitive Rates and Flexibility: We understand that cost-efficiency is crucial. That’s why we offer very competitive hire rates and flexible hire periods, including the option to “try before you buy” on some of our equipment. This ensures that our solutions align with the cooling demands of your business, both in terms of budget and operational requirements.

When you choose Newsome for your MRI chiller needs, you gain access to a wealth of experience, a wide range of  high quality equipment, and unwavering support. We are dedicated to helping you maintain the efficiency and reliability of your industrial processes, making us the ideal partner for all your cooling requirements.